Description
Serum amyloid A (SAA) is a sensitive acute phase reaction protein. Under normal circumstances, the content of SAA in plasma is less than 10 mg/L. When the body is stimulated by bacteria, viruses, mycoplasma, chlamydia and so on, the liver cells synthesize and secrete a large number of SAA into the blood. Therefore, SAA can be used as a sensitive indicator of the body's infection and inflammation control
Clinical significance
✔ Differential diagnosis of infectious diseases
✔ Risk forecast indicators of coronary heart disease
✔ Early sensitive indicators of organ transplantation rejection
✔ Dynamic observation index of curative effect and prognosis of tumor
Reagent performance
Sample type | Serum/plasma/whole blood/peripheral blood |
Linear range | 0.5-300 mg/L |
Precision within batch | ≤ 4% |
Precision between batch | ≤ 8% |
Reference range | ≤ 10 mg/L |
Application department
Laboratory Department, Emergency Department, ICU, Pediatric/Neonatology Department, Respiratory Department, Surgery Department, Hematology Department, Rheumatology and Immunology Department, Oncology Department, Nephrology Department, etc.
Product specification
Packing specification | Packing specification |
Biochemical packaging | 30 mL: R1:1x20 mL+R2:1x10 mL 60 mL: R1:1x40 mL+R2:1x20 mL 60 mL: R1:1x40 mL+R2:1x20 mL 120mL:R1:1x80 mL+R2:1x40 mL 120mL:R1:1x80 mL+R2:1x40 mL 270 mL:R1:3x60 mL+R2:2x45 mL |
Special protein packaging | Dose for 100 person Dose for 200 person Dose for 400 person |
Supporting instruments
Hitachi, Abbott, Beckman, Dirui, AU400 and other Automatic Biochemical Analyzer
✦Vazyme Specific Protein Analyzer PC-L3000
Description
Serum amyloid A (SAA) is a sensitive acute phase reaction protein. Under normal circumstances, the content of SAA in plasma is less than 10 mg/L. When the body is stimulated by bacteria, viruses, mycoplasma, chlamydia and so on, the liver cells synthesize and secrete a large number of SAA into the blood. Therefore, SAA can be used as a sensitive indicator of the body's infection and inflammation control
Clinical significance
✔ Differential diagnosis of infectious diseases
✔ Risk forecast indicators of coronary heart disease
✔ Early sensitive indicators of organ transplantation rejection
✔ Dynamic observation index of curative effect and prognosis of tumor
Reagent performance
Sample type | Serum/plasma/whole blood/peripheral blood |
Linear range | 0.5-300 mg/L |
Precision within batch | ≤ 4% |
Precision between batch | ≤ 8% |
Reference range | ≤ 10 mg/L |
Application department
Laboratory Department, Emergency Department, ICU, Pediatric/Neonatology Department, Respiratory Department, Surgery Department, Hematology Department, Rheumatology and Immunology Department, Oncology Department, Nephrology Department, etc.
Product specification
Packing specification | Packing specification |
Biochemical packaging | 30 mL: R1:1x20 mL+R2:1x10 mL 60 mL: R1:1x40 mL+R2:1x20 mL 60 mL: R1:1x40 mL+R2:1x20 mL 120mL:R1:1x80 mL+R2:1x40 mL 120mL:R1:1x80 mL+R2:1x40 mL 270 mL:R1:3x60 mL+R2:2x45 mL |
Special protein packaging | Dose for 100 person Dose for 200 person Dose for 400 person |
Supporting instruments
Hitachi, Abbott, Beckman, Dirui, AU400 and other Automatic Biochemical Analyzer
✦Vazyme Specific Protein Analyzer PC-L3000